TOCTAX TOC analyser, 1-100mg/L, 1 channel

UTGÅNGEN ARTIKEL

TOCTAX TOC analyser, 1-100mg/L, 1 channel
Produktnr: LPV375.00.00000

UTGÅNGEN ARTIKEL

Integrated digestion

High level of uptime

Precise measured values due to representative and homogenised sample

Proven self-cleaning system as standard

Low maintenance, simple and rapid

Specifikationer

Bredd: incl. cooling unit
Dimension (H x B x D): 1190 mm x 550 mm x 390 mm
Display : Graphics monitor with datalogger and curves display
Djup: incl. cooling unit
Höjd : incl. cooling unit
Kalibreringsintervall : Automatic at selectable intervals (duration: approx. 36 minutes)
Kapslingsklass: IP54
Mätintervall: T 100 16 to 18 min
Matningskrav (Hz): 50 Hz
Matningskrav (Spänning): 230 V AC
Mätområde: 1.00 - 100 mg/L TOC automatic switch over from 1.0-25/50/100mg/l C
Mätprincip: Based on DIN EN 1484 – wet chemical peroxide sulphate breakdown process with infrared spectroscopic detection (expulsion method)
Noggrannhet: ± 4 % + 0.1 mg/L (1.0 - 24.9 - 50 mg/L C)
  ± 5 % + 0,1 mg/L (1 - 100 mg/L C)
Omgivningstemperatur: 5 - 40 °C
Processanslutning: approx. 100 mL/h
  Atmospheric, 4/6 mm connection for waste, 8/11 mm for overflow tray (ID/OD)
Process connection (inlet): 3.2 mm OD
Process connection (installation style): (Analyser) Bypass; homogenisated water sample - wall mounting dry installation, protected against direct sunlight
Provtemperatur: 5 - 40°C (41 - 104°F)
Reagent capacitiy: 2 months (standard solution 3-6 months)
Reläer: 2 floating limit value contacts 24 V, 1 A
Specialkommentarer: Integrated refrigerator for reagent storage
  The chloride concentration (CI) in the sample must not exceed 400mg/l!
Standard accessories: Set of reagents, standard absorption solution, suitable for 2 month operations
Strömutgång: 2 x 0/4 to 20 mA max. 500 Ohm
  Service interface RS232
Strömutgång (option): PROFIBUS, MODBUS optional
Underhållsintervall: 3 månader
  approx. 1 hour per week
Vikt : 43 kg (without reagents)