EZ4041 Total Hardness Analyser, Instruction Manual, 1 x Double Bit Door Key, 1 x Mounting Brackets, 3 x empty 2.5L Reagent Containers with Fittings (for Buffer, Colour & Acid Solution) and 1 x empty 10L Reagent Container with Fittings (for EDTA Solution)

Specifikationer

Analoga utgångar: Active 4 - 20 mA max. 500 Ohm load, standard 1, max. 8 (option)
Antal provströmmar: 1, 2, 4 or 8
Certifieringar : CE compliant / UL certified
Cykeltid: 10 - 15 minutes
Demineralised water: For rinsing / dilution
Detektionsgräns: ≤ 10 mg/L
Digital outputs: Optional: Modbus (TCP/IP, RS485)
Dimension (H x B x D): 690 mm x 465 mm x 330 mm
Dränering: Atmospheric pressure, vented, min. Ø 32 mm
Earth connection: Dry and clean earth pole with low impedance (< 1 Ohm) using an earth cable of > 2.5 mm²
Garanti : 24 månader
Instrument air: Dry and oil free according to ISA-S7.0.01-1996 quality standard for instrument air
Kalibrering: N.A.
Larm: 1x malfunctioning, 4x user-configurable, max. 24 VDC/0.5 A, potential free contacts
Material: Hinged part: Thermoform ABS, door: PMMA
Wall section: Galvanised steel, powder coated
Mätmetod: Colorimetric titration by EDTA using colour indicator calmagite at 620 nm
Matningsspänning: 100 - 240 VAC, 50/60 Hz
Max. power consumption: 120 VA
Mätområde: 100 - 1000 mg/L CaCO3

Optional:
10 - 100 mg/L CaCO3
25 - 250 mg/L CaCO3
50- 500 mg/L CaCO3
Internal dispenser dilution (max. factor 100)
  100 - 1000 mg/L CaCO₃
Metodnamn: Titrimetric
Modell: EZ4041
Omgivningstemperatur: 10 - 30 °C ± 4 °C deviation at 5 - 95% relative humidity (non-condensing)
Parameter: Hardness, total
Precision: Better than 2% full scale range for standard test solutions
Prov: tryck: By external overflow vessel
Provflödeshastighet: 100 - 300 mL/min
Provkvalitet: Maximum particle size 100 µm, < 0.1 g/L; Turbidity < 50 NTU
Provtemperatur: 10 - 30 °C
Reagent Requirements: Keep between 10 - 30 °C
Skyddsklass: Protection class: Analyser cabinet: IP44 / Panel PC: IP65
Störningar: Some metal ions interfere by causing fading or indistinct end points or by stoichiometric consumption of EDTA. Suspended or colloidal organic matter also may interfere with the end point. Large amounts of colour and turbidity interfere. Fats, oil, proteins, surfactants and tar.
Vad ingår i leveransen: EZ4041 Total Hardness Analyser, Instruction Manual, 1 x Double Bit Door Key, 1 x Mounting Brackets, 3 x empty 2.5L Reagent Containers with Fittings (for Buffer, Colour & Acid Solution) and 1 x empty 10L Reagent Container with Fittings (for EDTA Solution)
Validation: Automatic; frequency freely programmable
Vikt : 25 kg