EZ6001 Total Dissolved Arsenic Analyser As(III+V)

EZ6001 Total Dissolved Arsenic Analyser As(III+V)
Produktnr: EZ6001.XXXXXXXX
Pris per st Kontakta oss

Vad finns i förpackningen

EZ6001 Arsenic Analyser, Instruction Manual, 1 x Double Bit Door Key, 1 x Mounting Brackets, 1 x Reference Electrode (Ag/AgCl), 1 x Working Electrode - Gold, 1 Counter Electrode, 1 x empty 5L Reagent Container with Fittings (Buffer Solution) and 1 x empty 10L Reagent Container with Fittings (H2SO4) and 2 x empty 1L Reagent Containers with Fittings (Reference Blank & Reference As Solution)

Specifikationer

Analoga utgångar: Active 4 - 20 mA max. 500 Ohm load, standard 1, max. 8 (option)
Antal provströmmar: 1, 2, or 4
Automatisk rengöring: Ja
Certifieringar : CE compliant / ETL certified
Cooling water: Not required
Cykeltid: 10 minutes
Demineralised water: For rinsing
Detektionsgräns: ≤ 1 µg/L
Digital outputs: Optional: Modbus (TCP/IP, RS485)
Dimension (H x B x D): 690 mm x 465 mm x 330 mm
Dränering: Atmospheric pressure, vented, min. Ø 32 mm
Earth connection: Dry and clean earth pole with low impedance (< 1 Ohm) using an earth cable of > 2.5 mm²
Garanti : 24 månader
Instrument air: Dry and oil free according to ISA-S7.0.01-1996 quality standard for instrument air
Kalibrering: Automatic, 2-point; frequency freely programmable
Larm: 1 x malfunctioning, 4 x user-configurable, max. 24 VDC/0.5 A, potential free contacts
Material: Hinged part: Thermoform ABS, door: PMMA
Wall section: Galvanised steel, powder coated
Mätmetod: Stripping voltammetry using gold electrode
Matningsspänning: 100 - 240 VAC, 50/60 Hz
Max. power consumption: 120 VA
Mätområde: 1 - 20 µg/L As
  1 - 20 µg/L As
Modell: EZ6001
Omgivningstemperatur: 10 - 30 °C ±4 °C deviation at 5 - 95% relative humidity (non-condensing)
Parameter: Arsenic, total dissolved As(III+V)
Precision: Better than 5% full scale range for standard test solutions
Prov: tryck: By external overflow vessel
Provflödeshastighet: 100 - 300 mL/min
Provkvalitet: Maximum particle size 100 µm, < 0.1 g/L; Turbidity < 50 NTU
Provtemperatur: 10 - 30 °C
Reagent Requirements: Keep between 10 - 30 °C
Skyddsklass: Analyser cabinet: IP44 / Panel PC: IP65
Störningar: Iodide, organic matter, copper Cu(II) > 30 µg/L, iron Fe(III) >20 mg/L, various metals in mg/L levels may interfere. Fats, oil, proteins, surfactants and tar.
Vad ingår i leveransen: EZ6001 Arsenic Analyser, Instruction Manual, 1 x Double Bit Door Key, 1 x Mounting Brackets, 1 x Reference Electrode (Ag/AgCl), 1 x Working Electrode - Gold, 1 Counter Electrode, 1 x empty 5L Reagent Container with Fittings (Buffer Solution) and 1 x empty 10L Reagent Container with Fittings (H2SO4) and 2 x empty 1L Reagent Containers with Fittings (Reference Blank & Reference As Solution)
Validation: Automatic; frequency freely programmable
Vikt : 25 kg