EZ3005sc Chloride Ion-Selective Electrode (ISE) Analyser, 1 stream, 4x mA

EZ3005sc Chloride Ion-Selective Electrode (ISE) Analyser, 1 stream, 4x mA
Produktnr: EZ3005.9800140T
Pris per st Kontakta oss

Reliable, Stable Measurements

Avoid downtime from unreliable ISE data caused by temperature fluctuations. The EZ3005sc stabilises both sample and electrode using a temperature controlled flow cell, eliminating measurement errors and delivering precise, repeatable chloride results operators can trust.

Lower Maintenance Effort

Minimise downtime and service costs with the EZ3005sc. Automated 2 point calibration, reagent alerts, a rugged ISE electrode, and minimal moving parts extend maintenance intervals; so operators spend less time servicing instruments and more time on plant operations.

Reduced Operating Cost

The EZ3005sc helps optimise operating costs by reducing chemical consumption and service visits. Multi stream capability monitors up to eight sample lines, lowering cost per sampling point and extending equipment life.

Designed for easy integration into existing control systems

With a wide range of analogue and digital outputs, this analyser aligns with plant specific requirements, ensuring compatibility with existing infrastructure and immediate access to real time measurement data.

Vad finns i förpackningen

EZ3005sc Chloride Ion-Selective Electrode (ISE) Analyser, 1 stream, Instruction Manual, 1 x Double Bit Door Key, 1 x Mounting Brackets, 1 x ISE Electrode and Chloride Electrode, combined, and 1 x empty 2.5L Reagent Container with Fittings (for Buffer Solution)

Specifikationer

Analoga utgångar: Active 0 - 20 mA (or 4 - 20 mA) max. 500 Ohm load, standard 4, optional: 8
Antal provströmmar: Standard: 1
Optional accessory for 2, 4, or 8 sample streams
Automatisk rengöring: Yes; Frequency freely programmable: 6 hours, 12 hours, daily, weekly
Certifieringar : CE, ETL certified to UL and CSA safety standards, UKCA
Cykeltid: Default: 5 minutes
Continuous: 5 minutes
Demineralised water: Does not apply
Detektionsgräns: 2 - 100 mg/L Clˉ: 2 mg/L
5 - 250 mg/L Clˉ: 5 mg/L
10 - 500 mg/L Clˉ: 10 mg/L
20 - 1000 mg/L Clˉ: 20 mg/L
Digital outputs: Relays: 5 contacts, not user configurable: Malfuntion, maintenance, analysis ready, sample ready, sample ready (EZ9150)

Ethernet Connections: Optional: Claros Ethernet connection and Modbus TCP/IP Ethernet connector; LAN version; 10/100 Mbps or Profinet or Ethernet IP

RS485 communication: Profibus DP or Modbus RTU
Dimension (H x B x D): 688 mm x 460 mm x 340 mm
Dränering: Atmospheric pressure, vented, min. Ø 32 mm
Earth connection: Earth connection Dry and clean earth pole with low impedance (< 1 Ohm) using an earth cable of > 2.5 mm²
Garanti : 24 månader
Instrument air: Dry and oil free according to ISA-S7.0.01-1996 quality standard for instrument air. Used to flush the instrument in corrosive environement. Min. 0.2 bar - Max. 0.5 bar
Kalibrering: Automatic; 2-point; Frequency freely programmable: 6 hours, 12 hours, daily, weekly. Note: manufacturer recommends that a calibration is done when the reagents are replaced
Material: Hinged part: Thermoform ABS, Door: PMMA
Wall section: Galvanised steel, powder coated
Mätmetod: Discontinuous, direct measurement by combined Ion-Selective Electrode
  Ion-Selective Electrode
Matningsspänning: 100 - 240 VAC, 50/60 Hz
Max. power consumption: 120 VA
Mätområde: 2 - 100 mg/L Clˉ
5 - 250 mg/L Clˉ
10 - 500 mg/L Clˉ
20 - 1000 mg/L Clˉ
Omgivningstemperatur: 10 - 30 °C ± 4 °C deviation at 5 - 95% relative humidity (non-condensing)
Parameter: Chloride
Precision: Better than 2% full scale range for standard test solutions
Prov: tryck: By external overflow vessel (open to atmospheric pressure)
Provflödeshastighet: 100 - 300 mL/min
Provkvalitet: Maximum particle size 100 µm, < 0.1 g/L; Turbidity < 50 NTU
Provtemperatur: 10 - 30 °C
Reagent Requirements: Keep between 10 - 30 °C
Skyddsklass: IP44
Störningar: Bromide [(Br)-], sulphide [(S)²-], iodide [(I)-], cyanide [(CN)-] ions may interfere. Mercury [(Hg)+] must be absent. Ammonia [NH₃] and thiosulphate [(S₂O₃)²-] may interfere. Fats, oil, proteins, surfactants and tar.
Vad ingår i leveransen: EZ3005sc Chloride Ion-Selective Electrode (ISE) Analyser, 1 stream, Instruction Manual, 1 x Double Bit Door Key, 1 x Mounting Brackets, 1 x ISE Electrode and Chloride Electrode, combined, and 1 x empty 2.5L Reagent Container with Fittings (for Buffer Solution)
Validation: Automatic; Frequency freely programmable: 6 hours, 12 hours, daily, weekly
Vikt : Max. 35 kg