SC1000 Givarmodul för 4 givare, 4x 4-20 mA UT, Prognosys, relä, 100-240 VAC, utan strömsladd

SC1000 Givarmodul för 4 givare, 4x 4-20 mA UT, Prognosys, relä, 100-240 VAC, utan strömsladd
Produktnr: LXV400.99.0U121
Pris per st Kontakta oss
Skickas inom 1 vecka

Flexibel: individuellt konfigurerbar

Available exclusively on the SC1000, Prognosys predictive diagnostics uses patented multivariable diagnostic software to read multiple inputs from your instrument and alert you to the instrument's overall performance. An easy-to-read dashboard provides instant indication of measurement reliability and service requirements.

Framtidssäker: alltid expanderbar

There’s no complicated wiring or set up procedures with the SC1000 controller. Plug any Hach digital sensor into a Probe Module and it’s ready for use. No special ordering or software configuration is needed.

Intuitivt handhavande: display med pekskärm

The SC1000 controller features state-of-the art Modbus TCP/IP communications protocol for seamless integration into a network of devices that support TCP/IP sockets. Use a standard Ethernet cable or connect wirelessly using GSM/GPRS to communicate with your SCADA, PLC or other network. The SC1000 also offers up to 12 analogue outputs for measured values and up to 12 analog or digital values from non-digital sensors.

Det finns många fler modeller på begäran

The SC1000 Controller can adapt to your needs. Add or change probes without having to change the controller. Plus, with a single Display Module, additional Probe Modules and associated sensors can be added or removed depending on operational needs. Fully upgradable software ensures that this system will not be obsolete. Hach service plans are available.

Vad finns i förpackningen

SC1000 Probe Module with installed cards (as requested), Basic User Manual

Specifikationer

Analoga utgångar: PID, high/low phasing, setpoint, deadband, overfeed timer, off delay, on delay
Analog Output: One 4-20 mA Output Module
Analogue inputs: No Input Module
Certifieringar : European Certifications:
CE per 73/23/EEC and 89/336/EEC
TUV-GS to EN 61010-1
EN 61326 Amd's 1 & 2
Conduit for Relay Connection: Nej
Dimension (H x B x D): 250 mm x 315 mm x 150 mm
Display : ¼ inch VGA graphical backlit TFT color Glas/Glas-Touch screen, high resistance 320 x 240 pixels
Displayvisningsområde: 11.4 x 8.6 cm
Garanti : 24 månader
Givares: 4
Ingångar: Up to 12 analogue 0-20 mA, maximum impedance 500 Ohms per probe module. Additional inputs are available with additional probe modules.
Kapslingsklass: IP65
Kommunikation: MODBUS (RS485): Avancerad kommunikation/nätverk med PLC eller SCADA system direkt från analysatorn
PROFIBUS DP/V1 (certifierad)
GSM/GPRS Quad-band modul (FCC och IC godkänd,endast EU och US )
Ethernet serviceport, RJ45, 10 MB/s
Kommunikationsmöjligheter: Ingen
Lagringsförhållanden: -20 - 70 °C / 0 - 95% relative humidity, non-condensing
Larm: Low alarm point, low alarm point deadband, high alarm point, high alarm point deadband, off delay, and on delay
Material: ABS (display module) and metal (probe module) enclosure with corrosion resistant finish
Matningsalternativ: 100 - 240 VAC, ingen matningskabel
Monteringsform: Yta, panel och rör (horisontellt och vertikalt) med solskydd som tillval
Omgivningstemperatur: -20 - 55 °C / 0 - 95% relative humidity, non-condensing
Prognosys: Ja
Reläer: 4 reläer, konfigurerbara, 100 till 230 V AC, max 5 A resistiv last per givarmodul. Fler reläer kan fås med ytterligare givarmoduler.
RTC Module: Nej
Utgång : Upp till 12 analoga 0/4-20 mA, max impedans 500 Ohms per givarmodul.





















Fler analoga utgångar med ytterligare givarmoduler. Tillbehör, digital kommunikation via Modbus® (RS485) och Profibus® DP/V1.
  Upp till 12 analoga 0/4-20 mA, max impedans 500 Ohms per givarmodul.





















Fler analoga utgångar med ytterligare givarmoduler. Tillbehör, digital kommunikation via Modbus® (RS485) och Profibus® DP/V1.
Vad ingår i leveransen: SC1000 Probe Module with installed cards (as requested), Basic User Manual
Vikt : Approximately 6.5 kg (depending on configuration)