CL17 Analysator

UTGÅNGEN ARTIKEL

CL17 Analysator
Produktnr: 5440001

UTGÅNGEN ARTIKEL

kolorimetrisk kemi - snabbt, enkelt och rätt

Snabb mätcykel

Komplett övervakning - minimalt underhåll

Robust och lätt kapsling

Vad finns i förpackningen

CL17 Chlorine Analyser with 1 Month Supply of Free Chlorine Reagents, Maintenance kit, Installation Kit, and Manual. (The power cord is ordered separately.)

Specifikationer

Arbetsluftfuktighet: Up to 90 % at 40 °C (104 °F) maximum
Beskrivning: CL17 Chlorine Analyzer with Reagents for Free Chlorine
Certifieringar : Europe, CE Approved with:
EN 61326-1
CISPR 11
EN 61010-1
IEC 60529

North America:
UL 61010A-1
CAN/CSA C22.2 No. 1010.1-92
Cykeltid: 2.5 min
Detektionsgräns: 0.03 mg/L (ppm)
Dimension (H x B x D): 454 mm x 314 mm x 179 mm
Display : LCD, 3-1/2 inch digit measurement readout and six-character alphanumeric scrolling text line
Dränering: 1/2-inch ID flexible hose, hose barb
Garanti : 24 månader
Inlopp: ¼" OD polyethylene tube, quick-disconnect fitting
Inloppstryck: 1 - 5 psi (0.07 - 0.34 bar), 1.5 psi (0.103 bar) is optimum
Kapsling: ABS plastic, two clear polycarbonate windows, IP62-rated with the gasketed door latched.
Kapslingsklass: IP62
Kommunikationsmöjligheter: 4-20 mA output
Larm: Two alarms selectable for sample concentration alarm, analyzer system warning, or analyzer system shut-down alarm. Each is equipped with an SPDT relay with contacts rated for 5A resistive load at 230 V AC.
Leveransomfattning: CL17 Chlorine Analyser with 1 Month Supply of Free Chlorine Reagents, Maintenance kit, Installation Kit, and Manual. (The power cord is ordered separately.)
Ljuskälla: Class 1 LED (light emitting diode) with a peak wavelength of 520 nm; 50,000 hours estimated minimum life
Luftspolning: 0.1 cfm (0.17 m³/h) instrument quality air at max. 20 psig (ca. 1.4 bar) with 1/4-inch OD tube, quick disconnect fitting
Matningskrav (Hz): 50/60 Hz
Matningskrav (Spänning): 100 - 115/230 V AC
Mätområde: 0 - 5 mg/L Cl₂
Monteringsform: Wall mount
Noggrannhet: ± 5 % or ±0.03 mg/L as CL₂, whichever is greater
Omgivningstemperatur: 5 - 40 °C max.
Parameter: Chlorine, Free & Total
Power requirements (Amps): 2,5 A
Pressure Regulator Included?: No
Provflödeshastighet: 200 - 500 mL per minute minimum
Provtemperatur: 5 - 40 °C (41 - 104 °F)
Repeterbarhet: 0.01 mg/L eller 3.0 % , beroende på vilket som är störst
Skrivarutgångar: One 0/4-20 mA with an output span programmable over any portion of the 0 to 5 mg/L range. Recommended load impedance 3.6 to 500 ohms, 130 V isolation from earth ground.
Störningar: Other oxidizing agents such as bromide, chlorine dioxide, permanganate and ozone will cause a positive interference. Hexavalent chromium will cause a positive interference:
1 mg/L Cr⁶⁺ = approximately 0.02 mg/L as Cl₂.
Hardness must not exceed 1,000 mg/L as CaCO₃.
Tillbehör: Ingen
Tillbehör som ingår: Ingen
Tryckområde: Inlet Pressure to Sample Conditioning: 1.5 - 75 psi (0.1 - 5.2 bar)
Vad ingår i leveransen: CL17 Chlorine Analyser with 1 Month Supply of Free Chlorine Reagents, Maintenance kit, Installation Kit, and Manual. (The power cord is ordered separately.)
Vikt : 10,49 kg